AL NAKHI POWER

INSTRUMENTATION CALIBRATIOn

Temperature Calibration System

  • Dry Block Temperature Calibrators
  • Black Body Calibration Sources
  • IR Thermometers

Dry blocks are versatile temperature calibrators that heat or cool a metal block to a specific temperature. Dry-block calibrators work well for calibrating straight, small diameter sensors such as RTDs, thermocouples, thermistors, PRTs, bi-metal thermometers, etc.

Different types of models are available based on the application.

· Range: -35°C from Ambient to 123°C

· Resolution: 0.01oC to 0.1°C

· Accuracy: ±0.3°C to ±1°C

· Stability: ±0.02°C to ±0.2°C

Black Body Calibrators were designed for calibrating infrared pyrometers with multiple temperature ranges.

Different types of models are available based on the application.

· Range: 10°C to 1200°C

· Accuracy: Within 0.5% F.S. to 0.75% F.S.

· Stability: ±0.5°C to ±1.5°C

· Resolution: 0.1°C

Infrared temperature calibrators use flat-plate (a metal disc painted black) or cavities (a metal tube painted black inside) that can be heated or cooled to different temperature test points and used to calibrate infrared temperature measuring devices.

Different types of models are available based on the application.

· Range: -50 to 1850°C (-58 to 3362°F)

· Accuracy: ±1.5% or ±1.5°C

· Repeatability: ±1% or ±1°C

Pressure Calibration System

  • Analog Gauge& Digital Indicators
  • Digital Pressure Indicators
  • Calibration Hand Pumps
  • Pressure Calibrators
  • Dead Weight Testers

Analog pressure gauges have a needle that directly responds to changes by pointing to numbers on a scale corresponding to the pressure sensed by the measuring element.

 

· Ranges / Models (in kg/cm2 or bar): 0 to 1000

· Accuracy: ±0.25% F.S.

Digital Pressure Indicators are designed to display system pressure using 3 or 4-digit ultra-bright LED display for checking & Calibration of Hydraulic Pressure / Differential Pressure Gauges / Switches / Transmitters / Receiver Gauges / Loops etc.

 

· Range: -1 to 1000 bar

· Accuracy: ±0.025% F.S. to ±0.1% F.S.

 

Pneumatic and Hydraulic types of Digital Pressure Indicators are available depending up on application

Calibration Hand Pump is used to generate pressure for the testing, adjusting and calibration of mechanical and electronic pressure measuring instruments like calibrating gauges, sensors, transmitters, transducers, and other pressure instruments in the field.

Pneumatic and Hydraulic hand pumps are available depending up on application.

· Range: -0.9 Bar Vacuum to 1000 Bar Pressure

· Medium: Air / Oil / Water (optional)

· Sensitivity / Resolution: 0.05 mBar / 0.5 mmWC to Upto 1 mBar

A pressure calibrator is simply a pressure measuring device capable of verifying (or calibrating) the pressure reading (UUT-Unit Under Test) with another pressure measuring device (Digital Pressure Indicators or Analog Pressure Gauges as Masters).

Different types of handheld Pressure calibrators and Portable Pressure Calibrators are available depending up on application.

· Range: -0.90 to 1000 bar

· Accuracy: ±0.025% F.S to ±0.1% F.S.

Dead weight tester is an instrument that calibrates pressure by determining the weight of force divided by the area the force is applied. Dead weights are usually used for pressure gauge calibration as they come with high accuracy, so they can be used as primary standard.

Different types of Dead Weight Testers are available depending up on their application and they are operated with oil (hydraulic) or with air (pneumatic).

· Ranges: 0.5 Bar Up to 1200 Bar

· Accuracy: ±0.015% to ±0.1% of Reading

· Piston: Single / Dual Piston (varies as per Model)

· Operating Fluid: Oil/Air/Gas

Calibration Test Benches

  • Calibration Test Benches

Calibration Test Benches are workstations for the maintenance and calibration of process instruments. Wide range of modules for calibration of electrical, pressure, temperature, and loop are available. Further modules and extras such as power supplies, oscilloscopes, and counters can also be integrated.

· Pressure Calibration Test Bench

· Temperature Calibration Test Bench

· Electrical / Electronic – Signal Calibration Test Bench

· Multifunction/Multiparameter Calibration Test Bench

· Corner Test Bench

· Student Teacher Training Test Bench

Process Flow Meter Calibration System

  • Process Flow Meter Calibration System
  • Mobile Flow Calibration System

Flow meter calibration is the process of comparing the pre-set scale or metering of a flow meter to a standard scale of measurement and adjusting its metering to conform to the standard. Calibration is an essential aspect of instrumentation in a broad range of industries that require high-accuracy measurements with a negligible percentage of error e.g., in Oil & Gas, Petrochemical, and manufacturing.

 

· Meter Sizes: From DN10 up to DN 400 (More Sizes optional)

· Calibration Methods: Gravimetric / Volumetric / Comparison

· Calibration Accuracies: ±0.2% up to ±0.05%

· Method of Operation: Manual / Semi / Fully Automatic

· Meter Sizes: From DN 6 up to DN 100

· Calibration Methods: Comparison

· Calibration Accuracies: ±0.3% to ±0.1%

· Method of Operation: Manual / Semi / Fully Automatic.

Level Calibration System

  • Level Calibration System

Primary & Interface Liquid Level Testing & Calibration of various models of Level Instruments including Inbuilt and external Chamber types. Most suited for calibrating both contact and non-contact type level Instruments

· Ranges: 1000 to 5000 mm (Chamber)

· Calibration Accuracies: ±0.05% FS

· Method of Operation: Simple/Basic, Manual/Semi-Automatic

· Calibration Methods: Comparison

Water Meter Calibration System

  • Water Meter Calibration System

Water Meter Calibration system is used to calibrate Domestic Water Meter (Water Meters used in Residentials, Hotels/Restaurants etc.). This type of system is mainly focused for OEMs, Calibration Laboratories & Calibration Service Providers.

· Water Meter Sizes: From DN15 up to DN 100 (More Sizes optional)

· Calibration Methods: Gravimetric / Volumetric / Comparison

· Calibration Accuracies: 0.2% up to 0.5%

· Method of Operation: Manual / Semi / Fully Automatic

Gas Meter Calibration System

  • Gas Meter Calibration System

Bell Prover type Gas Meter Calibration system is used to calibrate Domestic Gas Meter (Gas Meters used in Residentials, Hotels/Restaurants etc.). This type of system is mainly focused for OEMs, Calibration Laboratories & Calibration Service Providers.

· Gas Meter Sizes: G1.6, G2.5, G4, G6

· Accuracy: ±0.2% & ±0.5%

· Method of Operation: Simple/Basic, Manual/Semi-Automatic